American power conversion apc is a leading manufacturer of uninterruptible power supplies ups and surge protection products for endtoend legendary. If you need to return a product call the apc customer service department to obtain. Apc by schneider electric is not responsible for damage sustained during reshipment of this product. This is a very simple template to monitoring apc smart ups rt 8000xl. The snmp apc hardware sensor monitors performance counters on an apc ups device using the simple network management protocol snmp. Snmp data type upsbasicidentmodel na initial discovery ups model name, e. I couldnt find the values for run time remaining, battery capacity etc. Ups network management card 2 with environmental monitoring. How to get the most information out of your apc ups devices. Some of the stats seem to be unavailable on my model, though. Apc ups snmp battery replace sensor paessler knowledge base. Check for status of battery, temperature probes, voltage, load and much more. Kace k management appliance kace product support snmp oids power apc ups ups.
Snmp ups server apc pbe i have an old apc smartups 1500 rm sua1500rmi2u, and the bundled software powerchute business edition allows for retrieving stats over snmp. Apc smartups powerchute wo snmp linux zabbix apc template dedicated for notwindows apc powerchute business edition installations which dont. It looks like your ups isnt reacting to the normal mib that we used to create that sensor. Depending on your apc ups, the sensors can monitor the following properties. Free mgsnmpupsmib mib download search, download, and upload mibs. This object is used to locate the productspecific mib for this device. Powernet mib provided by american power conversion corp powernet mib file content. Apc smart ups rt 8000 xl this is a very simple template to monitoring apc smart ups rt 8000xl. You can import the mib with our mib importer and it looks like you will find the mib itself here. Based on the plugin by daniel duenas domingo, this adds quite a number of bugfixes, adds snmp v3 support and improved code logic and flow.
For information about the apc product you want to manage using the powernet mib, refer to the appropriate apc users guide or owners manual, for that product. Mge ups systems and mge office protection systems devices with snmp cards ref 66062, 66045, 66074 and 66244 apcc apc ap9605, ap9606, ap9617, and ap9618 apc network management cards, as well as any others supporting the apc powernet mib netvision socomec sicon ups with netvision websnmp management cardexternal box pw. Recently i acquired a second hand apc smartups 3000. Shows tags that this sensor inherits from its parent device, group, and probe. This setting is shown for your information only and cannot be changed here.
Reference guide 6 associated documents this guide describes how to use the powernet mib, only. See setting data via snmp in snmpinfo for general information on set operations. And all numerical values are presented as integers, meaning no decimals on voltages and temperatures even though. Nagios xi provides complete monitoring of apc ups battery backup systems. Nov 05, 2015 apc battery customsensor custom snmp sensor lookup snmp created on nov 5, 2015 2. Mge ups systems snmp mibs descriptions pdf, 78 kb mge usb devices draft aa official mge hid ups data pdf, 310 kb simplified shut protocol pdf, 63 kb utalk protocol general specifications pdf, 104 kb utalk command set specifications pdf, 288 kb utalk basic command set for ups single monitoring communication pdf, 7 kb.
Tripp lites snmpwebcard55 allows network users to operate any expansion slotequipped tripp lite smartpro or smartonline ups as a managed device on the network. User manual easy ups snmp card apv9602 schneiderelectric. Simple network management snmp mibs for 3com devices. Zbxapcups this template use the apcpowernetmib to discover and manage apc ups devices.
Free mg snmp ups mib mib download search, download, and upload mibs download mg snmp ups mib mib for free. Here you can find traps templtate for apc devices for netxms. Expand all pollers, check the box next to smartups and click next. My data flow is ups usb linux box apcupsd snmpd prometheus snmp exporter prometheus grafana. Most network devices and programs ship with socalled mib files to describe the parameters and meanings i. The location of the label as well as letter and number sequences will vary by model and product type. Implement nagios xi and eliminate problems before they affect your bottom line. You also use two mconfig oids to download new agent code to an adapter. I am not sure if it will work on all apcs but at least it is a start. Auvik can discover, monitor, and send you alerts on your apc uninterrupted power supplies ups. This video features the installation of powerchute on windows 2008 and its integration with an apc ups rt6000. Snmp monitoring for smartups snmp metrics catalog apc. Much to my surprise, there seemed to be lack of good snmp resources including how to install mibs and determine the oids i needed. Measureups, powerchute, powernet, snmp adapter, smartups and vs.
The name of the metrics generated by the exporter typically match the powernet mib. For smart ups models, this value is originally set in the factory. So the ups appaears to be a smartups 1500 which likely even have bypass. Therefore the ups should send a message to all servers via snmp. To do this im going to use parts of the tick stack, primarily telegraf for polling and data collection and influxdb for backend database heres a short introduction on those modules. Netbotz has a dedicated snmp mib excluding netbotz 200250. American power conversion corp snmp powernetmib file. Whether snmp agent is communicating with ups device 1 yes. These oids definitely work with the apc ap9617 management card which plugs in the back of apc devices. Combination of public and mostly private mibs object identifier oid property. By downloading, installing, loading, copying, or otherwise using the software. Get immediate notification of power outages and imminent server shutdown and be proactive with fast handling of network, server, application, and service outages.
I want a windows 2012 r2 server to shutdown on a power breakdown and the remaining power lasts for e. Free mgsnmpupsmib snmp mib download free mib download. Expand all nodes and select the apc smartups device from the list of orion monitored nodes and click finish. In the righthand side, select one of the four community names by clicking on the underlined link below community. Make ups information available to your preferred network, server or enterprise management system by forwarding snmp traps events using rfc 1628 mib. Powernetmib provided by american power conversion corp. Oct 24, 2018 recently i acquired a second hand apc smart ups 3000. To apply this undp to your apc ups equipment open the universal device poller as described above. What you may need to do is import the mib that is specific to your device and then create a library sensor with the import mib.
Snmpssl card is an interface between ups and the network. Any management card or smartsignalling powernet agent can. Let me know if something isnt quite correct so i can update. We are wanting to read snmp data for the following upses.
This is the mib module mg snmp ups mib from merlin gerin. Provides remote viewing of site electrical data, ups status information and selftest logs. On a single file server powered by an apc ups for serving any computer and. With the cheap addition of a network module snmp v2v3 support is easily added to this unit the next step is setting up monitoring. This document details the process to configure snmp polling and traps for apc smart ups, using the solarwinds network performance monitor rmm solution. Apc symmetra px40 3phase upsapc smartups vt 20kva 3phase upssmartups rt 7500 rm xland more. By default, prtg shows this name in the device tree, as well as in alarms, logs, notifications, reports, maps, libraries, and tickets parent tags. Home directory plugins network protocols snmp apc ups health and load. The wizard is available as a free download from the apc website at. Through the snmp nms and web browser, user can obtain the ups status, issue commands to ups and setting up the snmpssl card through the network. This oid tree represents the compiled snmp mib module mgsnmpupsmib and includes only highlevel compiled information. Any apc ups device that supports the powernet392 snmp mib.
Mge ups systems snmp mibs descriptions pdf, 78 kb mge usb devices draft aa official mge hid ups data. Ups mib powernet txt, 484 kb mib description pdf, 998 kb. Definitions ups mib definitions begin imports moduleidentity, objecttype, notificationtype, objectidentity, counter32, gauge32, integer32 from snmpv2smi displaystring, timestamp, timeinterval, testandincr, autonomoustype from snmpv2tc modulecompliance, objectgroup from snmpv2conf. Unlimited copies of the powernet mib may be used in conjunction with any. Apc managed services integration kits provide advanced snmp monitoring of apc smart ups with remote monitoring and management rmm solutions, using integrated snmp universal device pollers. About a dozen apc smart ups 2200s providing power to this equipment. Down the lefthand side, under snmpv1 select access control 5. Ive been meaning to rewrite an internal tool we i use at work to manage our apc pdus.
I am not sure if it will work on all apc s but at least it is a start. Display string upsadvidentdateofmanufacture na initial discovery, weekly. A fire suppression project requiring immediate shutoff of power to all servers in the event that the fire suppression agent is released to extinguish an electrical fire. Activexperts network monitor supports american power conversion corp mib files, to monitor. Administrative access to the webbased graphical user interface gui of the ups, and. Andrew update its seems that you need to changecorrect all parameters and then restart service to have any impact the ip address of the snmp. The powernet mib supports all apc network enabled devices except netbotz. Powernetmib provided by american power conversion corp powernetmib file content. Ups firmware update user friendly mechanism to remotely and seamlessly update ups firmware via the web browser interface smx, smt and srt smart ups only. Title page powernet snmp management information base. The snmpv2 network management framework the snmpv2 network management framework consists of four major components. The smartups and singlephase symmetra application firmware v6.
The powernet mib oids allow an nms to use its snmp browser to manage any of the following. Nagios live webinars let our experts show you how nagios can help your organization. These instructions worked for me on my apc smartups 5000 with a network management card running v5. Apcs smart protocol unofficial decoding work belkin. Please refer to knowledge base fa156148 for additional information and recommendations.
These instructions worked for me on my apc smart ups 5000 with a network management card running v5. Apc, backups, matrixups, measureups, powerchute, powernet, snmp adapter. Display string upsadvidentfirmwarerevision na daily the firmware revision of the ups systems microprocessor. Monitoring your apc ups with the tick stack and grafana ops. Module install instructions to install snmpinfolayer7apc, simply copy and paste either of the commands in to your terminal. The model number is not on the front of the unit, but can be found on a sticker on either the bottom or rear of your product. This guide describes how to use the powernet simple network management protocol snmp management information base mib v3. You can import the mib with our mib importer and it. Mge ups systems and mge office protection systems devices with snmp cards ref 66062, 66045, 66074 and 66244 apcc apc ap9605, ap9606, ap9617, and ap9618 apc network management cards, as well as any others supporting the apc powernet mib netvision socomec sicon ups with netvision web snmp management cardexternal box pw. For using traps you need configuring you network managment card, you can do this via card web interface. If you feel moved to monitor your apc ups, here are some of the oids youll want to use. Enables remote monitoring and control of ups and site electrical conditions using the snmp network management platform or a web browser. This is a very simple template to monitoring apc smartups rt 8000xl.
Apc smartups rt 8000 xl this is a very simple template to monitoring apc smartups rt 8000xl. Jun, 2011 apc set community name and nms server for snmp. Alert reportemailsms if ups is on battery power alert reportemailsms if ups is on ac mains power. Tried nightly build amd 64 rc shows same results no luck connecting to our apc ups via snmp any cluesrecommendations on parameters. I also have a nfin this directory if you list the directory. Title page powernet snmp management information base mib. The ups from apc has a network interface and additional a measurement modul for environment. So the ups appaears to be a smart ups 1500 which likely even have bypass. Unable to monitor smartups rt 8000 xl paessler knowledge base. Apc inline voltage and ups output voltage in vac 1,2,4 use snmp get for data input 3 gets data from a shell script due to the fact that runtime is in timeticks not gauge so require a little conversion to minutes, otherwise its also getting the input data through snmpget.
May 30, 2017 based on the apc powernet mib, prtg users have written a series of custom sensors that provide many values that the prtg snmp apc hardware sensor does not capture. Monitoring your apc ups with the tick stack and grafana. Manufacturer of power supply products designed to use with various electrical appliances. Activexperts network monitor download ships with advanced snmpmib tools. The prtg snmp apc hardware sensor delivers standard values about your apc hardware status.
Caution damage to the ups or websnmp management smartslot card ap9606 can result if you do not remove all ac and dc power from a smartups or matrixups model ups, smartslot expansion chassis ap9600, or smartslot expansion triple chassis ap9604, ap9604r or ap9604sr before you install the management card. In the drop down select the user name you just created 5. There just seems to be information about ip, mac, uptime and so on. This dashboard consumes data collected by a snmp daemon using apcupsd snmp, which is made available to prometheus by the prometheus snmp exporter. Smt750i actually theyre fujitsu branded fjt750i all upses have an ap9630 management card. It can obtain the status from a ups and issue commands to it. How to enable snmp on apc ups devices auvik support.
1344 1016 1586 175 545 1500 672 1271 694 104 981 119 415 1459 1368 131 1470 1130 636 1382 213 1087 239 964 999 438 444 1012 1556 1196 889 1333 1380 1445 1109 118 354 579 1368 905 324